یو پی اس MASTERYS GP - Green Power 2.0 range

یو پی اس MASTERYS GP - Green Power 2.0 range

from 10 to 120 kVA/kW

High availability, ultra high energy efficiency and maximum power available

The solution for

Data centres

Telecommunications

Service sector

IT Networks/ Infrastructures

Advantages

Energy saving + Full rated power = TCO

Energy Saving: high efficiency without compromise

Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems.

Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions, to have the value in the real site conditions.

Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.

Full-rated power: kW=kVA

No power downgrading when supplying the latest generation of servers in typical data centre conditions.

Full power UPS design up to 35 °C, with 25% more power compared to UPS with PF=0.8 and 11% more power compared to UPS with PF=0.9.

Suitable also for leading power factor loads down to 0.9 without derating.

Maximum energy saving thanks to 96% output efficiency: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.

UPS “self-paying” with energy saving.

Energy Saver mode for global efficiency improvement on parallel systems. kW=kVA means maximum power available with the same size of UPS, and therefore less €/kW

With its “clean rectifier“, Green Power UPS significantly optimize the upstream infrastructure without over rating the supply system (i.e. generator sets, switches, cables, protection devices).

High efficiency minimizes the amount of battery for an equivalent back-up time.

Battery configuration can be optimized, thanks to a very wide DC range.

Extended battery life and performance:

long life battery,

very wide input voltage (-40% / +20%) and frequency (45 to 65 Hz) without battery use,

EBS (Expert Battery System) charging management improves battery service life."

ویژگی های اختیاری و استاندارد

Advanced interface

Up to 30 languages embedded.

Colour graphic display.

Commissioning wizard.

Standard electrical features

Dual input mains.

Internal maintanance bypass.

Backfeed protection: detection circuit.

EBS (Expert Battery System) for battery management.

External temperature sensor.

Electrical options

External maintanance bypass.

External battery cabinet.

Additional battery chargers.

Galvanic isolation transformer.

Parallel kit.

ACS synchronization system.

Standard communication features

MODBUS TCP.

MODBUS/JBUS RTU.

Embedded LAN interface (web pages, email).

2 slots for communication options.

Communication options

Remote mimic panel.

Dry-contact interface.

PROFIBUS

NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance

LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC

داده های تکنیکی
Sn [kVA] 10 15 20 30 40 60 80 100 120 
Pn [kW] (0 °C ÷ 35 °C) 10 15 20 30 40 60 80 100 120
Input / output 3/1  •  •   •            
Input / output 3/3  •  •  •   •  •  •    •   •   •
Parallel configuration up to 6 units
Input
Rated voltage  400V 3ph + N
Voltage tolerances 240 V to 480 V(1)
Rated frequency  50/60 Hz ± 10%
Power factor/THDI > 0.99 / < 2.5%
Output
Rated voltage 1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (can be configured 380/415 V)
Voltage tolerance  static load ±1 % dynamic load in accordance with VFI-SS-111
Rated frequency  50 / 60 Hz
Frequency tolerance  ± 2% (configurable from 1% to 8%)
Total output voltage distortion - linear load < 1 %
Total output voltage distortion - non-linear load < 3%
Overload 125% for 10 minutes, 150% for 1 minute (1)
Crest factor  3:1
Bypass
Rated voltage rated output voltage
Voltage tolerance ± 15% (configurable with from 10% to 20%)
Rated frequency  50 / 60 Hz
Frequency tolerance  ± 2%
Efficiency (TÜV SÜD verified)
Online mode @ 50 % of load up to 96%
Online mode @ 75 % of load up to 96%
Online mode @ 100 % of load up to 96%
ECO MODE up to 98%
Environment
Operating environment temperature from 0 °C up to +35 °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity 0% - 95% without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m (ISO 3746) < 52 dB < 55 dB < 60 dB (A) < 65 dB (A)
UPS Cabinet
Dimensions (W x D x H) [mm] 444  x795   x800 444 x795  x1000 444 x 795 x 1400 600 x800  x1400 700x 800  x1930
Weight 190 kg 195 kg 195 kg 315 kg 320 kg 180 kg 200 kg

380
kg

460 kg
Degree of protection IP 20
Colours RAL 7012
Standards
 Safety EN 62040-1 (TÜV SÜD certified), EN 60950-1
 Performance EN62040-3 (VFI-SS-111)
 Electromagnetic compatibility (EMC) EN62040-2 
 Product declaration CE 

(1) conditions apply